` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.8 - No.1 (2014.03.20)
Title A rapid and sensitive detection of HPV by combined assay of PCR and fluorescence DNA chip
Authors Sung Joong Kim1, Ki Bong Nahm2, Jong Baeck Lim3, Sang Wook Oh4 & Eui Yul Choi1,5
Institutions 1BodiTech Med Inc., Chuncheon 200-160, Korea 2Department of Electronphysics, Hallym University, Chuncheon 200-702, Korea
3Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul 120-752, Korea
4Department of Biology Education, Institute of Fusion Science, Chonbuk National University, Jeonju 561-756, Korea
5Department of Biomedical Science, Hallym University, Chuncheon 200-702, Korea
Abstract A human papilloma virus (HPV) test can be used to identify women that are at risk for cervical cancer. Hybrid Capture (HC2) and PCR are the current gold standard assays and are used globally to detect HPV infection. We present a combined assay system that uses PCR and fluorescence (FL) DNA chip for simple, rapid, and sensitive HPV DNA detection. In the developed assay system, PCR-amplified DNA produced by biotin-labeled consensus GP5+/GP6+ primers was denatured, neutralized, mixed with FL-streptavidin detector solution and then the mixture was loaded onto the HPV DNA chip for DNA hybridization. The DNA chip was inserted into the laser FL scanner and the FL signal was measured. MgCl2 of PCR mixture completely nullified FL signal in DNA chip assay but addition of 50mM EDTA to detector solution recovered FL signal. When PCR product of HPV 16 or 18 infected patient?셲 sample was subjected to DNA chip assay, FL signal was observed only from its corresponding HPV type DNA chip, demonstrating the HPV assay system differentiate different HPV genotypes. In rapidity and sensitivity test, the FL signal was illuminated from a PCR product produced by 5 cycles, which did not resolve as a DNA band in gel electrophoresis, suggesting that the combined assay system is more sensitive than an HPV PCR assay. Additionally, this test can be completed within 30 minutes, which will allow patients to be evaluated for infection.
Keyword Capture oligoDNA, Fluorescence detector bead, DNA chip, HPV, PCR
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.