` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.1 - No.4 (2007.12.20)
Title Microbiochip for Electrical Detection of Carcinoembryonic Antigen Using Gold Nanoparticles and Silver Enhancement
Authors Joon-Ho Maeng1, Yong-Jun Ko2, Yoomin Ahn3, Nahm-Gyoo Cho3, Seoung-Hwan Lee3 & Seung Yong Hwang4
Institutions 1Department of Biochemistry, Graduate School, Hanyang University, Ansan, Gyeonggi-do 426-791, Korea 2Department of Precision Mechanical Engineering, Graduate School, Hanyang University, Seoul 133-791, Korea 3Department of Mechanical Engineering, Hanyang University, Ansan, Gyeonggi-do 426-791, Korea 4Division of Molecular and Life Science, Hanyang University and GenoCheck Co. Ltd., Ansan, Gyeonggi-do 426-791, Korea Correspondence and requests for materials should be addressed to S.Y. Hwang (syhwang@hanyang.ac.kr)
Abstract The conventional immunoassay protocol for the detection of carcinoembryonic antigen (CEA) is expensive, laborious, and time-intensive. Additionally, it requires a very large detection device. In an effort to solve these problems, we have asse-ssed the utility of a novel immunoassay technique based on microbeads and gold nanoparticles. In our microbiochip, we have adopted the filtration method to fix the microbeads, and used the immunogold silver staining (IGSS) method to amplify the electrical signal. The microbiochip was constructed of a Pyrex glass substrate and an inexpensive and biocompatible polydimethylsiloxane (PDMS) layer. The platinum (Pt) microelectrode for electrical signal detection was fabricated on the substrate. A microchannel and pillar- type microfilter was formed in the PDMS layer. The colon cancer marker, CEA, was assayed via a sandwich immunoassay. As a result, we obtained significant resistance signal as the difference in CEA concen-tration. The total analysis time was less than one hour. A bead-based electrical de-tection system, such as the one described in this study, can be applied to systems for cancer diagnosis.
Keyword Carcinoembryonic antigen, Immunoassay, Microbiochip, Immunogold silver staining, Microfilter, Microbead
PDF File Download
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.