Title Implantable Thin-film Porous Microelectrode Array (P-MEA) for Electrical Stimulation of Engineered Cardiac Tissues
Authors Hiren V. Trada1, Venkat Vendra2, Joseph P. Tinney3, Fangping Yuan3, Douglas J. Jackson1, Kevin M. Walsh1 & Bradley B. Keller3,*
Institutions 1Department of Electrical Engineering, Speed School of Engineering, University of Louisville, Louisville, KY, USA
2Department of Chemical Engineering, Speed School of Engineering, University of Louisville, Louisville, KY, USA
3Kosair Charities Pediatric Heart Research Program, Cardiovascular Innovation Institute, University of Louisville, Louisville, KY, USA
Abstract We have designed, fabricated, and validated a novel porous, multielectrode array (P-MEA) device capable of low-voltage electrical stimulation of engineered cardiac tissues (ECTs). The primary advantage of this device is the ability to successfully function at a very low voltage thus minimizing any undesirable oxidative by-products in the culture environment or cell injury. Major features of our P-MEA include dimensions of 10 mm width and 82 mm length, four arms to allow movement of the individual pads within ECTs, each embedded electrode arm incorporates eight 100 關m횞200 關m rectangular pores surrounding a 950 關m횞340 關m exposed electrode, large pads on either side of the porous embedded device to function as current return electrodes, suture holes to aid in vivo suturing and stabilization, and an eight electrode connector pads. Average thickness of the Ni/Au electrodes was 20 nm of nickel and 400 nm of gold, an average electrode film thickness of 0.4 關m, and a double polyimide layer thickness of 16 關m. Electrode resistance ranged from 69.45 廓 to 78.52 廓. Electrochemical impedance spectroscopy confirmed that the P-MEA operates in the 0.01 V to 1.0 V range with favorable charge transfer characteristics. Proof of principle experiments confirmed the ability of the P-MEA to effectively embed within ECT and electrically stimulate ECT during chronic, in vitro culture. Histology imaging shows that the embedding of the device has no adverse effects on the ECT and the cardiomyocytes are aligned within the tissue. Experiments are ongoing to evaluate the role of electrical stimulation on the maturation and function of ECTs.
Keyword Cardiac pacing, Heart failure, Micro electrode array, Thin film, Tissue engineering
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.