` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.10 - No.4 (2016.12.20)
Title Serological Tests for the Diagnosis of Infectious Diseases
Authors Soo-Kyung Kim1, Sang-Hyun Hwang2,3 & Heung-Bum Oh1,*
Institutions 1Department of Laboratory Medicine, University of Ulsan College of Medicine and Asan Medical Center, Seoul, Republic of Korea
2Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si 10408, Republic of Korea
3Hematologic Malignancy Branch, Research Institute and Hospital, National Cancer Center, Goyang-si 10408, Korea
*Correspondence and requests for materials should be addressed to H.-B. Oh (hboh@amc.seoul.kr)
Abstract Recent automated systems for the serological tests employing chemiluminescence immunoassay or electrochemiluminescent immunoassay give results within 30 minutes with high sensitivity and accuracy. However, false positive results are inevitable in serological screening for an infection due to the trade-off between sensitivity and specificity. A titration test has been used to confirm the screening results, but it is rarely performed. Instead, molecular tests are preferred in these days. Immunoassays were mostly qualitative in the past; however, quantitative kits have been developed and released on the market. The calibration step is necessary to report results quantitatively. As the calibration curve of an immunoassay is non-linear, four parameter or five parameter logistic models are adopted. analytical measurement range (AMR) verification should be performed periodically at least every six months in order to report quantitative results. Quantitative reporting is feasible only within a linear range that is verified by AMR evaluation. A new concept of quantitative measurement/qualitative reporting in immunoassays is introduced. Qualitative reporting even after the quantitative measurement has the advantage that periodic AMR verification is not required. This category can be applied if the accurate quantitative value is not clinically significant. Lately, the market of point-of-care testing (POCT) is growing rapidly due to an increasing need. Nevertheless, the performance of the serological POCT kits is much lower than that of automated systems for central laboratories. This limits the broad utilization of POCT, and thus research for enhancing its performance should continue.
Keyword Analytical measurement range, Calibration, Immunoassay, POCT, Serology
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.