` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.11 - No.1 (2017.03.20)
Title Assessment for Quantification of Biopharmaceutical Protein Using a Microvolume Spectrometer on Microfluidic Slides
Authors Jaehee Byeon1, Kui Hyun Kang1, Hoe-Kyung Jung2 & Jung-Keun Suh3,*
Institutions 1Bioanalysis, BIOnSYSTEMS, Inc. 2Newmedia Business, Seoul Media Institute of Technology 3Newmedia Content, Seoul Media Institute of Technology *Correspondence and requests for materials should be addressed to J.K. Suh ( jksuh@smit.ac.kr)
Abstract Spectrophotometric procedure is a traditional method for quantifying protein concentration in solution. The benefit of this method is simple and direct, not requiring standard materials, sample incubation, and exogenous chromophore addition. There are also some drawbacks, low detection limits and high amounts of protein needed. The recent advances in fiber optics and nano-technology enable to overcome those drawbacks by using microvolume sampling and extremely short pathlengths. In this study, the utility of the microvolume system with microfluidic carriers was assessed for concentration measurement of biopharmaceutical protein using absorbance at 280 nm and also compared to a traditional instrument. The results show a high correlation of estimation by Cohen?셲 d effect size and Pearson correlation coefficient between two different spectrometers. For UV spectral analysis, there are no statistically significant difference between those spectra from a microvolume spectrometer and a traditional one. For the extinction coefficient determination, two different spectrometers also give quite comparable and similar values. Thus a microvolume spectrometer can be used as an alternative over a traditional one to determine the concentration of biopharmaceutical protein. Moreover, the dynamic range for protein quantification by a microvolume pectrometer is over 10-fold higher than that of a traditional one.
Keyword Microvolume spectrometer, Protein quantification, UV absorbance, Extinction coefficient, Amino acid analysis
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.