` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.12 - No.4 (2018.12.20)
Title Development of Colorimetric Paper Sensor for Pesticide Detection Using Competitive-inhibiting Reaction
Authors Hyeok Jung Kim1, Yeji Kim1, Su Jung Park1, Chanho Kwon2 & Hyeran Noh1,3,*
Institutions 1Department of Optometry, Seoul National University of Science and Technology (Seoultech), 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
2Research Institute, Biomax Co., Ltd., Seoul Technopark, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
3Convergence Institute of Biomaterials and Bioengineering, Seoul National University of Science and Technology (Seoultech), 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
*Correspondence and requests for materials should be addressed to H. Noh (hrnoh@seoultech.ac.kr)
Abstract Contamination by pesticides is an everincreasing problem associated with fields of environmental management and healthcare. Accordingly, appropriate treatments are in demand. Pesticide detection methods have been researched extensively, aimed at making the detection convenient, fast, cost-effective, and easy to use. Among the various detecting strategies, paper-based assay is potent for real-time pesticide sensing due to its unique advantages including disposability, light weight, and low cost. In this study, a paper-based sensor for chlorpyrifos, an organophosphate pesticide, has been developed by layering three sheets of patterned plates. In colorimetric quantification of pesticides, the blue color produced by the interaction between acetylcholinesterase and indoxyl acetate is inhibited by the pesticide molecules present in the sample solutions. With the optimized paper-based sensor, the pesticide is sensitively detected (limit of detection=8.60 ppm) within 5 min. Furthermore, the shelf life of the device is enhanced to 14 days after from the fabrication, by treating trehalose solution onto the deposited reagents. We expect the paper-based device to be utilized as a firstscreening analytic device for water quality monitoring and food analysis.
Keyword Pesticide, Paper microfluidic, Colorimetric sensing, Three-dimensional paper device
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.