` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.6 - No.1 (2012.03.20)
Title A multi-inlet microfluidic device fabricated for in situ detection of multiple cytotoxicity endpoints
Authors Sanjeev Kumar Mahto1 & Seog Woo Rhee1
Institutions 1Department of Chemistry, Kongju National University, Kongju 314-701, Korea
Correspondence and requests for materials should be addressed to S.W. Rhee ( jisanrhee@kongju.ac.kr)
Abstract This work describes the development of a multi-inlet microfluidic device for in situ detection of multiple cytotoxicity endpoints. The device consists of an upstream microfluidic multi-inlet module (關MIM) and a downstream microfluidic cell culture channel (關CCC). The integration of a device with syringe pumps via the inlets of 關MIM mainly enables the performance of multiplex cytotoxicity assays targeted on multiple endpoints. The device in the study was used for the long-term culturing of BALB/3T3 fibroblast cells. In addition, cadmium ion was used as a toxicant to induce the toxicity in the cultured cells. The cytotoxicity endpoints, such as the in situ detection of reactive oxygen species (ROS), nuclear structures and cell morphology, were examined and correlated simultaneously for every single cell after they were exposed to cadmium. The data indicated that the percentage of cells that had produced ROS and shown nuclear staining were slightly higher than the cells that had produced ROS only, but this percentage was significantly higher than the cells that had shown only nuclear staining. The results revealed that the obtained correlated data from simultaneous observations of multiplex cytotoxicity assays were more efficient in providing the mechanistic explanation for Cd-induced toxicity than the individual data that were derived after examining a single endpoint. In addition, the results suggested that the intracellular formation of ROS induced by cadmium might have been followed by the alterations in cell and nuclear morphology and loss of membrane integrity. The device allows for the real-time monitoring of cells and their behavior against a toxicant and facilitates the rapid performance of cytotoxicity testing. Furthermore, we anticipate that the presented device could be very effective in advancing the understanding of the precise mechanism of cytotoxicity by improving the sensitivity and accuracy in identifying endpoints.
Keyword Microfluidics, Multi-inlet module, Cytotoxicity endpoints, Multiplex, Cytotoxicity assays
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.