` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.12 - No.2 (2018.06.20)
Title Dielectrophoresis Microfluidic Enrichment Platform with Built-In Capacitive Sensor for Rare Tumor Cell Detection
Authors Loc Quang Do1, Ha Tran Thi Thuy2, Tung Thanh Bui3, Van Thanh Dau4, Ngoc-Viet Nguyen5, Trinh Chu Duc3,* & Chun-Ping Jen5,*
Institutions 1University of Science, Vietnam National University, Hanoi, Vietnam
2Posts and Telecommunications Institute of Technology, Hanoi, Vietnam
3University of Engineering and Technology, Vietnam National University, Hanoi, Vietnam
4Research Group (Environmental Health), Sumitomo Chemical. Ltd, Japan
5Department of Mechanical Engineering, National Chung Cheng University, Chia-Yi, Taiwan, R.O.C.
*Correspondence and requests for materials should be addressed to C.-P. Jen (imecpj@ccu.edu.tw) and T.C. Duc (trinhcd@vnu.edu.vn)
Abstract The manipulation and detection of rare cells are important for many applications in early disease diagnosis and medicine. This study presents a dielectrophoresis (DEP) microfluidic enrichment platform combined with a built-in capacitive sensor for circulating tumor cell detection. The microchip is composed of a lollipop-shaped gold microelectrode structure under a polydimethylsiloxane chamber. A prototype of the device was fabricated using standard micromachining technology. With the proposed device, target cells (in this study, A549 non-small human lung carcinoma and S-180 sarcoma cell lines) are firstly guided toward the center of the working chamber via DEP forces. Then, the target cells are captured by an electrode immobilized by anti-EGFR, which has high affinity toward the target cells. After the cell concentration process, the differential capacitance is read to detect the presence of the target cells. Numerical simulations and measurement experiments were performed to demonstrate the high sensitivity of differential capacitive sensing. The obtained results show high sensitivity for S-180 cell detection (3 mV/cell). The proposed platform is suitable for rapid cancer diagnoses and other metabolic disease applications.
Keyword Rare cells, circulating tumor cell detection, dielectrophoresis (DEP) enrichment, capacitive sensor, differential measurement
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.