` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.13 - No.4 (2019.12.20)
Title High-Frequency Interdigitated Array Electrode-Based Capacitive Biosensor for Protein Detection
Authors Tuan Vu Quoc1,2, Viet Nguyen Ngoc2,3, Tung Thanh Bui3, Chun-Ping Jen2 & Trinh Chu Duc3,*
Institutions 1Institute of Applied Physics and Scientific Instrument, Vietnam Academy of Science and Technology, Hanoi, Vietnam
2Department of Mechanical Engineering, National Chung Cheng University, Chia-Yi, Taiwan, R.O.C.
3University of Engineering and Technology, Vietnam National University, Hanoi, Vietnam
*Correspondence and requests for materials should be addressed to Trinh Chu Duc (trinhcd@vnu.edu.vn)
Abstract This paper reports a study on developing of a protein detection biochip based on interdigitated array electrodes (IDAEs) capacitive immunosensor. The protein after being preconcentrated in a detection region will be selectively captured and detected by the capacitive immunosensor. Using electrical impedance spectroscopy operated at high-frequency in the range of 100 kHz–1 MHz, the capacitance of the gold electrode is determined and the antibody surface modification steps can be also monitored. The experiment results show the capacitance changes in accordance with the adding biochemical layer on gold electrodes for each step of the antibody surface modification. In particular, the total impedance operated at 1 MHz frequency has been seen to change from 2.1 kΩ of bare chip (before antibody surface modification) to 8 kΩ after antibody surface modification process while the serial capacitance is recorded to reduce steadily from 450 pF to 55 pF. Also, the efficiency of protein chip was investigated by implementing the measurement of 10 µM BSA with and without preconcentration process. The measurement results have shown the sensitivity increasing significantly after the protein is preconcentrated in this chip. The results demonstrate high efficiency of protein detection can be achieved by operating high frequency capacitive measurement on IDAEs capacitive immunosensor.
Keyword Capacitive immunosensor, Interdigitated array electrodes, Protein preconcentration, Protein detection, Impedance spectroscopy
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.