Title Sensitive Colorimetric Detection of Prostate Specific Antigen Using a Peroxidase-Mimicking Anti-PSA Antibody Coated Au Nanoparticle
Authors Xuan-Hung Pham, Eunil Hahm, Kim-Hung Huynh, Byung Sung Son, Hyung-Mo Kim & Bong-Hyun Jun*
Institutions Department of Bioscience and Biotechnology, Konkuk University, Seoul 143-701, Republic of Korea
*Correspondence and requests for materials should be addressed to B.-H. Jun (bjun@konkuk.ac.kr)
Abstract The use of colorimetric bioassays for protein detection is one of the most promising diagnostic approaches, but their relatively poor detection limits have been a critical issue. In this study, we developed an efficient colorimetric bioassay based on antibody-coated peroxidase-mimicking Au nanoparticles (Au NPs) for the detection of prostate-specific antigen (PSA), which is one of the most widely used protein biomarkers for the diagnosis of prostate and breast cancers. Anti-PSA antibody adsorption on the Au NP surface result in 65% of the peroxidasemimicking properties of Au NPs was suppressed to maximize sensitivity of the assay. Anti-PSA antibody adsorption on the Au NP was optimized at 150 µg/mL anti-PSA4 antibody for 1 h incubation, and their surface was blocked with 2% BSA. The experimental conditions of the immunoassay detection were also investigated. A highest assay value was obtained at 10 µg/mL anti-PSA1 capture antibody using 3% BSA for surface blocking and at 2.5 pM anti- PSA4-Ab coated Au NPs for 1 h incubation with PSA antigen. As a result, PSA was detected at a wide range of 0.25 to 2,500 ng/mL with a detection limit of 0.23 ng/mL. The anti-PSA-Ab coated Au NP- based assay was simple, easy to operate, and sensitive. The proposed peroxidase-mimicking anti-PSA Ab-coated Au NPbased assay could be further developed to detect other protein biomarkers.
Keyword Colorimetric Detection, Prostate Specific Antigen, Prostate Cancer, Peroxidase-mimicking, Anti-PSA-Ab coated Au nanoparticle
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 신관 804호     대표자 : 심상준, 고유번호 : 206-82-65403
대표전화 : 070-7767-9855 , 팩스 : 02-921-9856 , 전자우편 : biochip@biochip.or.kr, 웹사이트 : http://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.
Facebook Twitter URL 복사