` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.14 - No.3 (2020.09.20)
Title An On-chip Chemiluminescent Immunoassay for Bacterial Detection using in Situ-synthesized Cadmium Sulfide Nanowires with Passivation Layers
Authors Hong-Rae Kim1, Ji-Hong Bong1, Jaeyong Jung1, Jeong Soo Sung1, Min-Jung Kang2, Jae-Gwan Park2 & Jae-Chul Pyun 1,*
Institutions 1Department of Materials Sciences and Engineering, Yonsei University, 50 Yonsei-Ro, Seo-dae-mun-gu, Seoul 120-749, Korea
2Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 136-791, Korea
*Correspondence and requests for materials should be addressed to J.C. Pyun (jcpyun@yonsei.ac.kr)
Abstract The passivation layers of an in situ-synthesized cadmium sulfide (CdS) nanowire (NW) photosensor were prepared for two reasons: (1) to improve the physical stability of the NW on an interdigitated electrode and (2) to enhance the immobilization efficiency of proteins for the on-chip immunoassay. The passivation layer was estimated to have suitable optical properties, and the photoresponse of photosensor was increased after the formation of passivation layer. The immobilization efficiency of a parylene-H film through covalent bonding was compared with the immobilization of Z-domains through physical adsorption. Finally, on-chip chemiluminescent immunoassay of bacteria was carried out by immobilizing antibodies against Escherichia coli through Z-domains for the orientation control of antibodies. The limit of detection was determined to be less than 104 E. coli/mL (n=3), and the sensitivity of bacterial detection was estimated to be 0.339 pA/E. coli/mL (n=3) with a linearity factor (R2) of 0.999. These results showed that the on-chip chemiluminescent immunoassay for bacterial detection could be performed using passivation layer coated CdS NW photosensor.
Keyword CdS nanowire, Photosensor, Surface passivation, On-chip immunoassay
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.