` The Korean BioChip Society
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society



BT+IT+NTThe Korean BioChip Society

BioChip Journal

Current Issue

Info. Vol.8 - No.2 (2014.06.20)
Title Decoration of Carbon Nanotube Films with Iridium Nanoparticles and Their Electrochemical Characterization
Authors Muhammad Irfan1, Xuan-Hung Pham1, Kwi Nam Han1, Cheng Ai Li1, Myung Hyo Hong1 & Gi Hun Seong1,*
Institutions 1Department of Bionano Engineering, Hanyang University, Ansan 425-791, Korea
Abstract We report the development of a novel nonenzymatic glucose sensor based on single-walled carbon nanotube film electrodes coated with iridium nanoparticles (IrNPs-SWCNT). The SWCNT film electrode was first loaded with iridium nanoparticles (IrNPs) by an easily controllable chronocoulometry technique. The SWCNT film electrode coated with IrNPs was characterized by field emission scanning electron microscopy and electrochemical techniques like cyclic voltammetry (CV) and amperometry. There was no current response for glucose oxidation in neutral and acidic media, but a couple of oxidative and reductive peaks were observed when the IrNPs-SWCNT electrode was scanned in alkaline media, showing the strong electrocatalytic activity toward glucose oxidation. Amperometric measurements showed a high sensitivity of 63 關Acm-2 mM-1 and a detection limit of 17 關M; further, the measurements showed a linear range of 0.59-14mM. To improve the selectivity of the electrode, the prepared IrNPs-SWCNT film electrode was coated using a 1.0% Nafion aqueous solution. When the electrodes were exposed to interfering substances such as uric acid and ascorbic acid, there were no significant signals observed from these substances, indicating that Nafion is an effective permselective polymer barrier. The sensitivity of the Nafion-coated electrode was 23關Acm-2 mM-1 and the detection limit was 47 關M. In addition, the electro-catalytic activity of the Nafioncoated electrode was still stable after 50 cycles in the presence of a 3.0 mM glucose solution as measured by CV.
Keyword Electrocatalysis, Iridium nanoparticles, Carbon nanotubes, Electrochemical deposition, Glucose
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.