` The Korean BioChip Society
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society



BT+IT+NTThe Korean BioChip Society

BioChip Journal

Current Issue

Info. Vol.10 - No.1 (2016.03.20)
Title A Reagent-Ready-on-Chip Microfluidic Immunoassay System for Rapid Detection of Influenza A H1N1 and H3N2 Viruses
Authors Kin Fong Lei1,2,*, Jun-Liang Liu1, Chia-Hao Huang1, Rei-Lin Kuo3,4,5 & Ngan-Ming Tsang6,7
Institutions 1Graduate Institute of Medical Mechatronics, Chang Gung University, Taoyuan, Taiwan ROC
2Department of Mechanical Engineering, Chang Gung University, Taoyuan, Taiwan ROC
3Research Center for Emerging Viral Infections, Chang Gung University, Taoyuan, Taiwan ROC
4Graduate Institute of Biomedical Sciences, Chang Gung University, Taoyuan, Taiwan ROC
5Department of Medical Biotechnology and Laboratory Science, Chang Gung University, Taoyuan, Taiwan ROC
6School of Traditional Chinese Medicine, Chang Gung University, Taoyuan, Taiwan ROC
7Department of Radiation Oncology, Chang Gung Memorial Hospital, Linkou, Taiwan ROC
Abstract Development of effective disease screening method is the best approach for the control of infectious diseases. However, conventional screening methods require to operate in well-equipped laboratory. That makes the screening operation expensive and time-consuming. In this work, a reagent-ready-on-chip microfluidic immunoassay system was developed and rapid detection of influenza A H1N1 and H3N2 viruses was demonstrated to show its simplicity and rapidity. The microfluidic system integrated 4 single-stroke thermopneumatic actuators and a reaction chamber. All related reagents were pre-installed in the system and manipulated automatically for indirect immunoassay. Detection of influenza A H1N1 and H3N2 viruses based on its internal structure protein, i.e., nucleoprotein (NP), was demonstrated using the system. Result was represented by colorimetric signal in the reaction chamber. The use of thermopneumatic actuation could achieve fluid manipulation without external assistive equipment and colorimetric result could be observed directly without the need of external dedicated detector. Influenza virus screening could be completed around 1 hour with less sample volume (20 關L) and reagent volume (50 關L). The system achieved one-step operation of immunoassay. It is highly integrated and has potential to be developed to portable devices to realize rapid diagnostics in remote environment and clinics without well-equipped facility.
Keyword Microfluidic system, Immunoassay, Influenza virus, Portable device, Rapid diagnostics
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.