Title Improvement of Droplet Speed and Stability in Electrowetting on Dielectric Devices by Surface Polishing
Authors Hamidreza Shirinkami1,??/sup>, Jiman Kim2,??/sup>, Choonghee Lee2, Hee Chan Kim3 & Honggu Chun1,*
Institutions 1Department of Biomedical Engineering, College of Health Science, Korea University, Seoul, Republic of Korea
2Interdisciplinary Program for Bioengineering, Seoul National University, Seoul, Republic of Korea
3Department of Biomedical Engineering, Seoul National University, Seoul, Republic of Korea
??/sup>These authors contributed equally to this study.
*Correspondence and requests for materials should be addressed to H. Chun (chunhonggu@korea.ac.kr)
Abstract This paper reports on a technique that significantly improves the performance of open-plate electrowetting on dielectric (EWOD) devices by using chemical mechanical polishing (CMP) to achieve surface planarization. In EWOD devices, trenches are inevitably generated during fabrication, and these can have a considerable effect on droplet manipulation. Such artefacts lead to a local intensification in the electric field that not only hinders the droplet movement due to a partially increased adhesion force, but also limits the maximum applicable potential by increasing the likelihood of a dielectric breakdown. We conducted theoretical and experimental studies on the effect of trenches on the performance of both unpolished and polished EWOD devices. Various combinations of the droplet volume and electrode size were tested, and our proposed technique resulted in a notable improvement for all cases. For instance, when operating at 100 V, a 3.5 關L droplet could be translated at 70 mm/s on the polished EWOD device, which is twice as fast as that for its unpolished counterpart at the same voltage. Also, the maximum applicable potential resulting in a dielectric breakdown of the polished EWOD device was measured to be 27% higher than that of a conventional device.
Keyword Digital microfluidics, electrowetting on dielectric (EWOD), droplet microfluidics, dielectric breakdown, chemical mechanical polishing (CMP)
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.