Title A Simple Liquid Crystal-based Aptasensor Using a Hairpin-shaped Aptamer for the Bare-Eye Detection of Carcinoembryonic Antigen
Authors Huihui Ren & Chang-Hyun Jang*
Institutions Department of Chemistry, Gachon University, Seongnam-daero1342, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
*Correspondence and requests for materials should be addressed to C.H. Jang (chjang4u@gachon.ac.kr)
Abstract Sensitive detection of carcinoembryonic antigen (CEA) is highly important in clinical diagnosis because CEA is an effective tumor marker associated with gastric, lung, rectal, and breast cancers. Thus, the development of an accurate, simple, and efficient method for the detection of CEA remains a long-term clinical goal. In this study, a liquid crystal-based aptasensor was constructed for the label- free and sensitive detection of CEA. The aptamer, as a molecule identification element, was immobilized onto (3-aminopropyl)triethoxysilane (APTES)- and dimethyloctadecyl[3-(trimethoxysilyl) propyl]ammonium chloride (DMOAP)-modified surface slides through glutaraldehyde (GA); this aptamer can specifically bind to CEA. In the presence of CEA molecules, the loop-stem structure of the aptamers coated onto the surface of the slides opens, and the aptamer then combines with CEA, leading to the formation of aptamer- CEA complexes, which causes the orientation of the liquid crystal molecules (LCs) to transition from a homeotropic to a random alignment. This transition can easily be observed using polarized light microscopy, based on the change of dark optical images into bright ones. The aptasensor system is quite sensitive, as the detection limit is as low as 0.12 pg/ml, with a linear equation of Grayscale=20.318logCCEA+26.329 (R2=0.9925), for a CEA concentration range of 0.05 pg/ml to 50 ng/ml. Bovine serum albumin (BSA) and human serum albumin (HSA) were also tested in this experiment, indicating that this sensor can selectively distinguish between CEA and other interfering compounds with similar protein structures. Moreover, these results were further confirmed by atomic force microscopy (AFM) and ellipsometry.
Keyword liquid crystal, 4-cyano-4′-pentylbiphenyl (5CB), carcinoembryonic antigen (CEA), aptamer, optical image
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.