Title Clinical Evaluation of a Novel Micro-lancet (ML) for Minimizing Lancing Pain
Authors Yonghao Ma1, Chisong Lee1, Ghunil Lee2, Yonggeun Cho3, Sang-Guk Lee3,* & Hyungil Jung1,4,*
Institutions 1Department of Biotechnology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
2Department of Biomaterials Science and Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
3Department of Laboratory Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
4Juvic Inc., 272 Digital-ro, Guro-gu, Seoul 08389, Republic of Korea
*Correspondence and requests for materials should be addressed to H. Jung (hijung@yonsei.ac.kr) and S.-G. Lee (comforter6@yuhs.ac)
Abstract Patients with diabetes are required to lance their fingers daily for self-monitoring their blood glucose level. Patients might be reluctant to use commercial lancets with thick outer diameters due to lancing pain; this results in the worsening of their health. A metallic microneedle is an ideal substitute to the commercial lancet system and offers a minimally invasive and patient friendly approach for capillary blood extraction. However, reports regarding the performance of sufficient long and high stiffness microneedles for innocuous and efficient capillary blood sampling for conducting clinical trials are rare. Here, we developed a novel micro-lancet (ML) that is 3 mm long and has a 130 μm outer diameter and a sharp beveled 15° tip. ML induced lesser tissue damage than the commercial ACCU-CHEK Softclix in a porcine skin test. Through a clinical study, we demonstrated that the pain scores using the commercial lancet and ML were 3.4 and 0.8 the numeric pain rating scale, respectively. The average blood volume drawn using the ML was 0.96 μL, which satisfies the minimum requirement (0.3 μL) for glucose detection. This novel ML may improve patient compliance to blood glucose monitoring procedures by reducing lancing- related pain.
Keyword Clinical evaluation, Capillary blood sampling, Micro-lancet, Microneedle, Pain
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.