Title Optical-Switch Raman Spectroscopy for High Throughput Screening
Authors Seung-Jin Lee 1 , Kwan Hee Lee 2, Young-Wan Choi 1, Jun Ki Kim 2,3*, Woo June Choi 1*
Seung-Jin Lee : First author.
*Jun Ki Kim kim@amc.seoul.kr
*Woo June Choi cecc78@cau.ac.kr
Institutions 1School of Electrical and Electronics Engineering, Chung- Ang University , Seoul 06974, Republic of Korea
2Department of Medical Science, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
3Department of Biomedical Engineering, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
Abstract Although surface-enhanced Raman spectroscopy (SERS) is a powerful analytical technique with unbeaten sensitivity, the capabilities of SERS have been not fully utilized in screening applications because throughput of spectrum detection by conventional Raman instruments has been restricted due to their single-point measurement manners. Hence, this paper presents a development of a high throughput Raman screening system that employs a fiber-optic switch and a Raman probe
array. In the system, a 785 nm excitation light is directed into the 1 × 8 broadband optical switching device and selectively switched to one of 8 output ports connected to the corresponding Raman probe array to deliver the light to samples under each probe. This optical switching driven probing in sequence allows us to rapidly detect Raman scattering of the multiple (n = 8) samples in array within a short time (~ 28 s) with decent sensitivity (10 –7 M). The Raman spectroscopy of the system is validated by comparing the features of Raman spectra obtained from vitamin C tablets with those from a commercial Raman microscope and the detection sensitivity is measured with SERS substrates with different concentrations. Then, feasibility of high throughput screening is tested with a SERS chip array.
Keyword Raman spectroscopy, Surface enhanced Raman spectroscopy (SERS), High throughput screening (HTS), Multi-point measurement, Optical switch
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

Address : Room 804, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea (06130)
TEL : +82-70-7767-9855 , FAX : +82-2-921-9856 , E-MAIL : biochip@biochip.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.