` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.7 - No.3 (2013.09.20)
Title An evaluation of a real-time passive micromixer to the performance of a continuous flow type microfluidic reactor
Authors Pin-Chuan Chen1
Institutions 1Mechanical Engineering Department, National Taiwan University of Science and Technology, Taipei, Taiwan
Abstract Microfluidics has been developed as an important platform for biochemical/chemical reactions. How to enhance the performance of a microfluidic chemical reactor is one of the core concerns when designing the microfluidic device. In the pressure-driven microfluidics without micromixer, parabolic flow profile dominates the behaviors of the laminar flow as well as the reaction particles such as DNA fragments, proteins, and enzymes. The aim of this study is to elucidate and answer a question: does a groove-shape passive micromixer improve the performance of a continuous flow type microfluidic reactor? Two mold inserts were micro-milled in the experiments, one had regular microchannels and the other one had regular microchannels with groove-shape passive micromixers, and both polymeric chips were manufactured with hot embossing techniques. Multiple experiments were realized on both chips to evaluate the groove-shape passive mixer to the performance of a continuous flow type microfluidic reactor. Polymerase chain reaction (PCR) is a typical example of chemical reaction in microfluidics, a 99 bp DNA fragment from 貫-DNA was used as the target in the experiments. In this study, multiple experiments were carried out, analyzed, and concluded that the groove-shape passive mixing is not beneficial to the performance of a continuous flow type microfluidic reactor. The results showed that a regular microfluidic device without mixing had better amplification efficiency of the target DNA fragments, which indicated that using a real-time passive mixing component inside a continuous flow environment, increasing the chance of protein absorption and strengthening shear force to molecules, might cause the negative impact to the PCR reaction performance.
Keyword Microfluidics, Miniaturized chemical reactor, Micromilling, Passive micromixer, Microchannel
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.