` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.5 - No.3 (2011.09.20)
Title Increase in the detection sensitivity of a lateral flow assay for a cardiac marker by oriented immobilization of antibody
Authors Yiseul Ryu1, Zongwen Jin1, Mun Suk Kang2, & Hak-Sung Kim1,3
Institutions 1Department of Biological Sciences, KAIST, Daejon, Korea
2 LG Innotek Ltd., Ansan, Korea
3Graduate School of Nanoscience and Technology, KAIST, Daejeon, Korea
Correspondence and requests for materials should be addressed to H.-S. Kim ( hskim76@kaist.ac.kr)
Abstract Early detection of human cardiac markers is regarded as a gold standard for diagnosis of acute myocardial infarction (AMI). Here we demonstrate the increase in the detection sensitivity of a lateral flow assay for a cardiac marker troponin I (cTnI) by oriented immobilization of antibodies on magnetic beads. For the construction of sensitive magnetic labels, orientated-immobilization of anti-troponin I antibodies on magnetic beads was attempted using protein G. Magnetic beads were first conjugated with protein G followed by immobilization of anti-cTnI antibodies. The factors affecting the detection sensitivity in the lateral flow assay system were investigated. The lateral flow assay of cTnI was carried out using the magnetic beads and a Giant magnetoresistive (GMR) sensor at the optimized conditions, and compared the results with using a conventional random immobilization method. Magnetic labels with oriented immobilization of antibodies enabled the detection of cTnI up to 0.01ng/mL, showing significantly increased sensitivity compared with conventional immobilization method. This result clearly shows that the magnetic labels with oriented immobilization of antibodies can find wide applications in the lateral flow assays of target analytes.
Keyword Protein G, Lateral flow assay, Oriented immobilization, Magnetic bead, Cardiac Troponin I (cTnI)
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.