` 학술지 열람 - 학술지(BCJ) : (사)한국바이오칩학회 (The Korean BioChip Society)
Go to contents

(사)한국바이오칩학회 The Korean BioChip Society





BT+IT+NT융합시대의 리더 : 한국바이오칩학회

학술지 열람

논문 정보 자세히 보기

Info. Vol.15 - No.4 (2021.12.20)
Title Ultraviolet Fluorescence-Based Quantitative Detection of Polycyclic Aromatic Hydrocarbons
Authors Vien Thi Tran1,2, Joo Seon Seok1,2, Injun Yoon3 & Heongkyu Ju1,2,*
Institutions 1Department of Physics, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
2Gachon Bionano Research Institute, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
3Research and Development Department, Daeyoon Scale Industrial Co., Ltd, Seoul, Republic of Korea
Abstract Polycyclic aromatic hydrocarbons (PAHs), mainly produced by incomplete combustion of organic materials in ship engines as well as in industry, has been considered one of the major hazardous substances in water-based ecotoxicology. Its realtime quantitative monitoring has thus been becoming increasingly important, particularly that with ultrahigh sensitivity. In this work, we demonstrated an ultraviolet (UV) fluorescence with an optical feedback for the highly sensitive quantitative detection of polycyclic aromatic hydrocarbons (PAHs). A fluorescence sensor is presented owing to its intrinsic fluorescence properties in the UV spectral range. This sensor, where an optical feedback is introduced with an aluminum film coated on a sensor chip, enhances fluorescence via increasing efficiency of both dye excitation and emission collection. The experimental results include the linear response of the UV fluorescent signal-to-concentration over a broad concentration range, with the signal-to-concentration slope representing a threefold enhancement over conventional fluorescence devices. The sensor device features such characteristics as the limit of detection (LOD) of 0.49 part per billion (ppb), signal accuracy > 92.5%, coefficient of variation < 5% (for signal reproducibility), the detection time of 3 s, and temperature error < 5%. Upon miniaturization of the format, the device presented may find an use for ultrasensitive in situ detection of PAHs in water.
Keyword Ultraviolet fluorescence-based sensor, Polycyclic aromatic hydrocarbon detection, Fluorescence enhancement, Optical sensors
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.