Info.
|
Vol.17 - No.1 (2023.03.20) |
Title
|
Fluorescent Lateral Flow Assay with Carbon Nanodot Conjugates for Carcinoembryonic Antigen
|
Authors
|
Jung Min Lim1, Mulya Supianto1, Tae Yang Kim2, Byeong Soo Kim2, Jeong Woo Park2, Hyun Hee Jang2, Hye Jin Lee1
*Hyun Hee Jang hh.jang@kthd.co.kr
*Hye Jin Lee hyejinlee@knu.ac.kr
|
Institutions
|
1Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-Gu, Daegu 41566, Republic of Korea
2R&D Center, Kick the Hurdle, 18, Yongdong-ro 57beon-gil, Uichang-gu, Changwon-si, Gyeongsangnam-do 51139, Republic of Korea
|
Abstract
|
A lateral flow assay (LFA) sensor on a half-strip platform labeled with blue carbon nanodot-polystyrene (PS-CND) nanoconjugates was developed for the detection of carcinoembryonic antigen (CEA) levels in buffer and serum solutions from healthy and cancer patients. CNDs, biocompatible nanoparticles containing amino groups synthesized by hydrothermal synthesis, were conjugated to spherical polystyrene (PS) beads with an average diameter of 60 nm, followed by the attachment of a detection probe, anti-CEA (M0911042), using a heterobifunctional cross-linker. PS beads were used as a template in CND conjugates to provide uniform size and shape of fluorescent labels without losing CND fluorescence intensity after the antibody conjugation step and to improve fluorescence stability. Upon the interaction of CEA from samples with the anti-CEA (M0911042) probe-modified PS-CND, which was further adsorbed onto a test line composed of the capture antiCEA (M0911041) physisorbed onto a nitrocellulose membrane, the fluorescent signals on the test line increased as a function of the CEA concentrations under irradiation with a portable 365 nm ultraviolet lamp. A linear concentration range of 0.04–70 nM in buffer was observed, with a limit of detection of 0.3 nM. The applicability of the developed LFA half-strip sensor for disease diagnosis was demonstrated by identifying fluorescent levels on the test line due to the presence of CEA in serum samples from cancer patients. Importantly, signals from healthy human serum solutions because of lower CEA concentrations beyond the sensor detection capability were clearly distinguished from the patient ones.
|
Keyword
|
Lateral flow immunoassay, Polystyrene, Carbon nanodots, Carcinoembryonic antigen, Serum analysis
|
PDF File
|
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
|