Info. Vol.18 - No.1 (2024.03.20)
Title Numerical-Simulation-Based Buffer Design for Microchip Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
Authors Jianyun   Meng 1,Nebiyu   Getachew   Arega 1,Bhargav   Krishna   Pullagura 1,Dohyun   Kim 1*
* Dohyun Kim dohyun.kim@mju.ac.kr
Institutions 1Department of Mechanical Engineering , Myongji University , 116 Myongji-ro , Yongin   17058 , Republic of Korea
Abstract We present a numerical simulation method for designing a buffer system in microchip electrophoresis (MCE) equipped with capacitively-coupled-contactless-conductivity detection (C4D). One of the key design considerations for MCE-C4D is background electrolyte (BGE). This is because a C4D typically exhibits low sensitivity, and optimizing BGE conditions (e.g., base and acid species, pH, and ionic strength) can improve its sensitivity. However, BGE has been traditionally designed through experience or trial and error, which is time- and reagent-consuming. In this study, we employ Simul 5, an open- source electrophoresis simulation software, for rational BGE design. Four BGEs including trimethylamine (TEA)/acetic acid (AcOH, pH 10.6), MES/His (pH 6.1), MES/TRIS (pH 8.1), and TRIS/HCl (pH 7.4), previously used in electrophoresis-C4D of amino acids and protein, were selected for evaluation of our numerical method. Glutamic acid (Glu) was selected as a model analyte for initial simulation verification. Our numerical simulation revealed that the best achievable detection sensi- tivity was 1.046 × 10 –5 S/(m μM) in the TRIS/HCl buffer because anionic Glu species with a low mobility (27 × 10 –9 m 2/Vs) replaced Cl − co-ion of a high mobility (79.1 × 10 –9 m 2/Vs) in the analyte zone, leading to a significant negative conductivity peak. TEA/AcOH, MES/His, and MES/TRIS buffers exhibited progressively lower sensitivity. After the initial evaluation, trypsin inhibitor (TI), a more complex proteinous analyte was tested in the MES/His and MES/TRIS BGEs. The best detec- tion sensitivity was 1.032 × 10 –4 S/(m μM) in the MES/TRIS buffer because counter-ionic species TRIS + of a high mobility (29.5 × 10 –9 m 2/Vs) was replaced by the ionic TI, characterized by a large charge (− 11.5) and a low mobility (8.08 × 10 –9  m2/ Vs), resulting in a strong negative peak. Based on a comprehensive analysis of the impacts of compositional changes in each
ionic species of the analyte zone on conductivity-peak height, we propose a BGE design guideline for enhanced sensitivity. Subsequent MCE-C4D confirmation experiments demonstrated excellent qualitative agreement with the simulation results
for the Glu and TI analytes. We anticipate that our numerical analysis method will find wide application in designing BGEs for portable MCE-C4D systems by enhancing sensitivity.
Keyword Microchip electrophoresis (MCE)  · Capacitively coupled contactless conductivity detection (C4D)  · Background electrolyte (BGE)  · Buffer system design  · Simul 5  · Glutamic acid  · Trypsin inhibitor
PDF File
# 2010년도 발행분 부터는 Springer 의 BioChip Journal 페이지에서 전문을 열람하실 수 있습니다.
# 학회회원 로그인 후 [ Springer BioChip Journal 열람하기 ] 버튼을 클릭하시면 새창으로 열립니다.
→ 전체 목록 보기

(사)한국바이오칩학회 (The Korean BioChip Society)
총괄/후원/부스/저널/학술대회
전화 : 070-7767-9855
전자우편 : biochip@biochip.or.kr
등록/초록/학술대회/e-컨퍼런스/
회원정보/홈페이지
전화 : 070-7767-9867
전자우편 : biochip2@biochip.or.kr
주소 : (우)06130, 서울특별시 강남구 테헤란로7길 22 과학기술회관 1관 804호    대표자 : 박현규   고유번호 : 206-82-65403   팩스 : 02-921-9856
웹사이트 : https://www.biochips.or.kr Copyright © The Korean BioChip Society. All Rights Reserved.